SMART-UPS SRT 1000VA RM 230V

Ensure continuous power protection with the APC SMART-UPS SRT 1000VA RM 230V. This double-conversion online UPS delivers 1 kVA/1000 W and features 432 Joules of battery backup, making it ideal for sensitive equipment requiring stable voltage supply

 Stores where to buy this product

Sponsored  This site contains affiliate links for which we may receive compensation. More information
This product has not been found in any sponsored store recently, please check similar products from our sponsors or review other stores we offer where you may find the product.

 Similar products

Sponsored


CHECK PRODUCTS/PRICES ON THE WEBSITE
This product in Comparor
Category
This product is cataloged in our store in these categories
International
Find this product in one of our international stores
it
2076.90 EUR
be
2150.17 EUR
fr
2081.48 EUR
at
1834.76 EUR
de
1848.35 EUR
Colors
Predominant colors of the product
Identifiers
Brand APC

APC is a brand that specializes in making high-quality, durable, and functional clothing and accessories for men and women. The brand is known for its simple and timeless designs, as well as its focus on quality and functionality. APC is a favorite among fashion-savvy individuals for its unique and stylish pieces.
MPN APC SRT1000RMXLI-NC
ID 27287165
Dimensions / Weight
Key Features
Audible alarm(s) Yes
Battery recharge time 1 h
Battery technology
The chemical composition or classification of a battery, such as lithium‑ion, lithium‑polymer, nickel‑metal hydride, sealed lead acid, alkaline, zinc‑air, etc. It indicates the type of electrochemical reaction that stores and delivers energy in the device.
Sealed Lead Acid (VRLA)
Battery voltage
The electrical potential difference supplied to or measured across a battery’s terminals, expressed in volts (V). It represents the battery’s nominal operating voltage and is used to match power sources, chargers, and devices that require a specific voltage level.
48 V
Colour
The colour or combination of colours that a product is available in, expressed as common names such as "Black", "Silver" or comma‑separated lists like "Black, White". It indicates the visual appearance of the item for consumers.
Black
Display type
The type of visual panel or display technology used in a product, such as LCD, LED, OLED, TFT, IPS, AMOLED, or analog. It indicates the underlying technology that determines image quality, color reproduction, power consumption and suitability for different use cases.
LCD
Harmonized System HS code
The Harmonized System (HS) code is a standardized numerical identifier used internationally to classify traded goods. It consists of up to six digits, where each pair of digits represents progressively more specific product categories. The HS code facilitates customs duties, trade statistics, and regulatory compliance by providing a common language for describing products across borders.
85078000
Input frequency 40/70 Hz
International Protection IP code
The IP (Ingress Protection) code indicates a product’s resistance to solids and liquids. It follows the standard two‑digit format (e.g., IP20, IP67), where the first digit represents protection against solid particles and the second against liquids. The code may include an ‘X’ to denote unknown protection for that category or multiple codes separated by commas for products offering different levels of protection in various configurations.
IP20
Maximum input operation voltage
The highest electrical voltage that a device can safely accept from its power source, expressed in volts (V). It indicates the maximum supply voltage compatible with the product and is used to ensure proper operation across different regions and power standards.
150 V
Maximum output operation voltage
The highest electrical voltage that a device can safely produce or deliver on its output terminals, expressed in volts (V). It indicates the maximum output level for power supplies, UPS units, and other equipment where the user may need to know the peak voltage available for connected loads.
240 V
Minimum input operation voltage
The lowest electrical voltage that the product is designed to accept from its power source, expressed in volts (V). It indicates the minimum mains or battery supply required for safe and reliable operation.
50 V
Minimum output operation voltage
The lowest electrical voltage that a device’s output can provide or operate at, expressed in volts (V). It indicates the minimum supply level required for the product to function correctly and helps users verify compatibility with power sources and accessories.
220 V
Operating relative humidity
The range of relative humidity (in percentage) within which the product is designed to operate reliably. Values are expressed as a minimum–maximum interval such as "20 - 80 %" and indicate the acceptable environmental moisture level for optimal performance.
0 - 95 %
Operating temperature
The range of temperatures in which a product can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
0 - 40 °C
Output Frequency 50/60 Hz
Output Power
The electrical power that a device can deliver or consume, expressed in watts (W). It represents the actual power output under normal operating conditions and is useful for comparing performance across similar devices.
1000 W
Products per pallet 12 pc(s)
Serial interface type
The type of serial communication interface supported by the product, such as RS‑232, RS‑485, RJ‑45, or SATA. It indicates which physical connectors and protocols are available for data exchange with other devices.
RJ-45
Storage temperature
The range of temperatures in which a device can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
-20 - 50 °C
Surge energy rating
The amount of electrical energy, measured in joules (J), that a device can absorb during a surge event before failure. It indicates the level of protection against voltage spikes and is useful for comparing surge protectors, UPS units, and other power‑conditioning equipment.
432 J
Sustainability certificates
A list of environmental, safety or quality certifications that a product has obtained from recognized authorities. Typical entries include RoHS, ENERGY STAR, CE, WEEE, TCO Certified, FCC, and other industry‑specific standards.
RoHS
UPS topology Double-conversion (Online)
Waveform
The shape of the electrical voltage or current produced by a power supply, expressed as a string such as "Sine", "Square", or "Triangle". It indicates how the output varies over time and affects noise levels, harmonic distortion, and compatibility with electronic equipment.
Sine

Related articles

Discover the APC AP8702S-WW Power Cord Kit, featuring six locking power cords with C13 to C14 connectors, each measuring 0.61 meters for secure and flexible connectivity in various settings. Ideal for ensuring reliable power supply connections.
Ensure continuous power for critical devices with the APC SMART UPS ONLINE, featuring a robust 1 kVA double-conversion design.
Ensure secure installation of your APC Rack ATS with the versatile AP7768 Bracket Kit. This rear rail solution simplifies mounting and enhances flexibility for efficient data center management.
Split Feed Through Side Panels Black in Colour APC Net Shelter SX 48U 1200
This 6' wide, high capacity vertical cable manager for 2 and 4 Post open frame racks features a single-sided cable channel Multiple internal cable tie-off locations and smooth plastic fingers at 1U increments for organized patching applications
🤖 Hello! I'm your virtual assistant. I can help you find products, compare prices and answer questions about your orders. Where should we start?
Chatbot service provided thanks to Gemini 3 / OpenAI using Comparor’s database. The AI may make mistakes — always verify the information.
Comparor AI BETA
Online
Restart the conversation?