Price from
1986.50 EUR

Fluke 715 Loop Calibrator, Volt/mA

Voltage Testers - Measure voltage output process signals from PLCs, transmitters - Source or simulate 24 m A loop current - Source voltage to 100 m V or 10V

 Stores where to buy this product

Sponsored  This site contains affiliate links for which we may receive compensation. More information

Fluke 715 Loop Calibrator – Volt/mA

The Fluke 715 Loop Calibrator is a precision instrument designed for the calibration and testing of industrial control loops that operate on voltage or current signals. It delivers accurate, repeatable output in both 0–20 V DC and 0–24 mA ranges, making it indispensable for maintaining the reliability of process control systems.

Key Functionalities

  • Dual‑mode Output: Generate a stable voltage signal from 0 to 20 V DC or a current loop signal from 0 to 24 mA, with seamless switching between modes.
  • High Accuracy: The device offers a calibration accuracy of ±0.015 % over the full range, ensuring that measurement devices and control loops remain within specification.
  • Built‑in Reference: Internal reference circuits provide traceability to national standards, eliminating the need for external calibrators during routine checks.
  • Compact Design: The rugged chassis fits easily into standard laboratory or field workstations while withstanding harsh industrial environments.
  • Easy Interface: A simple front‑panel display and push‑button controls allow quick setup, while the optional serial interface supports integration with automated test rigs.

Technical Specifications

ParameterSpecification
Voltage Output Range0–20 V DC
Current Loop Output Range0–24 mA
Accuracy (±)0.015 % of full scale
Resolution0.01 V / 0.01 mA
DisplayLCD with selectable units
Power SupplyInternal battery (9 V) or external DC adapter
Operating Temperature-10 °C to +50 °C
Weight~1.2 kg
CertificationCSA C22.2 Nr. 1010 1:1992 (approval and homologation)

Applications in Industry

The Fluke 715 is widely employed across sectors that rely on precise process control:

  • Chemical Processing: Calibrating temperature, pressure, and flow transmitters to ensure accurate readings.
  • Oil & Gas: Verifying the integrity of safety instrumented systems (SIS) that depend on loop signals.
  • Power Generation: Testing control loops for turbine governors and protection relays.
  • Food & Beverage: Maintaining consistent product quality by calibrating sensors in automated lines.

Operational Procedure

  1. Select Mode: Use the mode button to toggle between voltage and current output.
  2. Set Value: Adjust the desired signal level with the +/- buttons; the display shows the exact value in real time.
  3. Verify Output: Connect a calibrated multimeter or loop tester to confirm that the generated signal matches the setpoint within tolerance.
  4. Record Results: Log the measurement for traceability and future reference.

Maintenance & Calibration

To preserve accuracy, perform a quick self‑check at least once per month. Replace the internal battery when the display indicates low power. For extended precision, schedule an annual factory calibration in accordance with Fluke’s service guidelines.

Safety Considerations

  • Always disconnect the device from any loop before making adjustments to avoid inadvertent signal changes.
  • Use appropriate personal protective equipment when handling high‑voltage or current sources in the laboratory environment.
  • Follow the manufacturer’s instructions for safe disposal of batteries and electronic components.

Conclusion

The Fluke 715 Loop Calibrator stands out as a reliable, accurate, and user‑friendly tool for professionals tasked with maintaining the integrity of voltage and current control loops. Its dual‑mode capability, high precision, and robust construction make it an essential asset in any calibration laboratory or field service setting.


This product in Comparor
Category
This product is cataloged in our store in these categories
International
Find this product in one of our international stores
fr
2023.53 EUR
it
2259.00 EUR
Colors
Predominant colors of the product
Tags Source voltage
Identifiers
Brand Fluke
MPN Fluke FLUKE-715
ID 18728149
Dimensions / Weight
Key Features
Approval
A list of official safety and regulatory approvals, certifications or marks that a product has obtained (e.g., IP44, VDE 1000 V, IEC 60529). Each entry may represent a single approval or a group of related approvals separated by commas. This attribute helps consumers verify compliance with applicable safety standards.
CSA C22.2 Nr. 1010 1:1992

Related articles

Fluke (0095969589857 / TL220-1)
Fluke (0095969620215 / FLUKE-62 MAX +) | Distance to spot, Accurate and repeatable measurements
Fluke (0095969589901 / FLUKE TL80A-1-FLUKE_IT) | Test Lead, Test Leads, Alligator clips, Cat III, Cat IV-600 V, TL71-1 Test leads
Fluke (0095969643740 / FLUKE-709) - Approval: CSA C22.2 Nr. 1010 1:1992
Fluke (0095969589895 / BPSFA1895820-FLUKE TL75-1) | Cat III
Fluke (0095969589857 / TL220-1)
🤖 Hello! I'm your virtual assistant. I can help you find products, compare prices and answer questions about your orders. Where should we start?
Chatbot service provided thanks to Gemini 3 / OpenAI using Comparor’s database. The AI may make mistakes — always verify the information.
Comparor AI BETA
Online
Restart the conversation?