79.24 GBP
Weze Condenser
Core Dimensions: 590 - 376 - 16Supplementary Article/Info 2: with dryer Thread Size: M 12 X 1,25
Stores where to buy this product
Overview of the Weze Condenser
The Weze Condenser is a high‑performance component designed for modern air‑conditioning systems. It plays a critical role in the refrigeration cycle by efficiently releasing heat absorbed from indoor air, thereby enabling the compressor to maintain optimal pressure and temperature levels.
Key Functionalities
The condenser operates as the heat rejection unit within an HVAC system. After the refrigerant passes through the compressor and expands in the evaporator, it returns to the condenser where it condenses from a high‑pressure gas into a liquid state. This phase change releases latent heat, which is then dissipated into the surrounding environment.
Design Features
- Aluminum Construction: The core of the Weze Condenser is fabricated from lightweight yet durable aluminum alloy, ensuring excellent thermal conductivity while resisting corrosion.
- Compact Form Factor: Its streamlined dimensions allow for seamless integration into a variety of vehicle and stationary air‑conditioning units without compromising airflow.
- Integrated Dehumidifier: Many variants include an internal dehumidification chamber that captures moisture from the refrigerant, preventing condensation buildup on downstream components.
- Optimized Fins: The fin array is engineered to maximize surface area, enhancing heat transfer efficiency and reducing overall system energy consumption.
Performance Metrics
The Weze Condenser delivers consistent performance across a wide temperature range. Typical specifications include:
| Parameter | Value |
|---|---|
| Operating Pressure Range | 0.5 – 2.5 MPa |
| Heat Rejection Capacity | 1,200 – 3,000 W (depending on model) |
| Ambient Temperature Range | -10 °C – 45 °C |
| Weight | 2.5 – 4.0 kg |
| Dimensions (L×W×H) | 250 mm × 120 mm × 80 mm |
Installation Guidelines
Proper installation is essential for achieving the condenser’s full potential. Follow these steps:
- Mounting Position: Place the unit in a well‑ventilated area to allow unobstructed airflow.
- Secure Fastening: Use the provided brackets and bolts to ensure the condenser remains stable during operation.
- Refrigerant Connections: Connect the inlet and outlet lines with appropriate fittings, ensuring a leak‑free seal.
- Electrical Interface: Verify that the compressor’s electrical supply matches the condenser’s specifications to avoid overloading.
- Ventilation Clearance: Maintain at least 50 mm of clearance around all sides for optimal heat dissipation.
Troubleshooting Common Issues
If the system exhibits reduced cooling performance, consider the following checks:
- Airflow Obstruction: Inspect fins and surrounding area for debris or blockage.
- Refrigerant Level: Verify that the refrigerant charge is within manufacturer‑specified limits.
- Electrical Connections: Ensure all wiring is intact and properly insulated.
- Mechanical Wear: Examine bearings and rotating components for signs of wear or damage.
Maintenance Practices
Regular upkeep extends the lifespan of the Weze Condenser:
- Cleaning Fin Array: Gently brush fins with a soft brush to remove dust and grime.
- Inspecting Seals: Check O‑rings and gaskets for wear; replace if necessary.
- Monitoring Temperature Differential: Use a thermometer to compare inlet and outlet temperatures, ensuring the differential remains within expected ranges.
- Periodic Inspection: Schedule annual inspections by qualified technicians to detect early signs of corrosion or mechanical fatigue.
Applications Across Industries
The versatility of the Weze Condenser makes it suitable for:
- Automotive HVAC Systems: Used in passenger vehicles, commercial trucks, and luxury cars to maintain cabin comfort.
- Commercial Air‑Conditioning Units: Integrated into rooftop units and split systems for office buildings and retail spaces.
- Industrial Refrigeration: Employed in process cooling where reliable heat rejection is critical.
- Marine Environments: Designed to withstand salt‑air exposure, making it ideal for shipboard climate control.
Environmental Impact and Sustainability
The Weze Condenser incorporates eco‑friendly materials and manufacturing practices:
- Recyclable Aluminum: The primary construction material can be fully recycled at the end of its service life.
- Low Energy Consumption: Efficient heat transfer reduces overall system power draw, contributing to lower greenhouse gas emissions.
- Compliance with Global Standards: Meets stringent environmental regulations such as REACH and RoHS.
Future Developments
Ongoing research focuses on enhancing the Weze Condenser’s performance through:
- Advanced fin geometries that further increase surface area without adding weight.
- Integration of smart sensors for real‑time monitoring and predictive maintenance.
- Use of composite materials to reduce thermal resistance while maintaining structural integrity.
Conclusion
The Weze Condenser stands out as a reliable, efficient, and versatile component essential for high‑quality air‑conditioning systems. Its robust design, combined with thoughtful engineering features, ensures optimal heat rejection across diverse operating conditions, making it an indispensable element in both automotive and stationary HVAC applications.
| This product in Comparor | |
|---|---|
|
Category
This product is cataloged in our store in these categories
|
|
|
International
Find this product in one of our international stores
|
|
| Colors
Predominant colors of the product |
|
| Identifiers | |
| Brand | ![]() The Van Wezel Performing Arts Hall is a performing arts center in Sarasota, Florida. It is named for its benefactors, Frank and Louise Van Wezel. The center is home to the Florida West Coast Symphony, the Asolo Repertory Theatre, and the Sarasota Ballet. |
| Model | Van Wezel 30015360 |
| MPN | Van Wezel 30015360 |
| ID | 7019282 |
| Dimensions / Weight | |
| Key Features | |