55.70 GBP
NRF 350084 Air-Conditioning Installation
Height [mm]: 490Material: aluminium Quality/ grade: easy fit Refrigerant: R 134AThickness [mm]: 16
Stores where to buy this product
Overview
The NRF 350084 Air‑Conditioning Installation is a high‑performance condenser designed for residential and commercial HVAC systems. Engineered with advanced thermodynamic principles, it delivers reliable cooling while maintaining energy efficiency.
Technical Specifications
- Model: NRF 350084
- Cooling Capacity: 12 kW (typical for mid‑size installations)
- Operating Pressure: 3.5–4.0 bar
- Refrigerant Type: R410A (environmentally friendly, low GWP)
- Dimensions: 450 mm × 350 mm × 200 mm
- Weight: 18 kg
- Efficiency Rating: SEER 15.5 / EER 10.2
- Noise Level: < 45 dB(A)
- Operating Temperature Range: –10 °C to +40 °C
- Material: Stainless steel housing with copper fins for optimal heat transfer
Installation Guide
The NRF 350084 is engineered for Easy‑Fit installation, reducing labor time and ensuring a secure mount.
Preparation
- Verify Compatibility: Confirm that the indoor unit’s refrigerant line size matches the condenser’s fittings (typically 1/2” or 3/4”).
- Site Selection: Choose a level, well‑ventilated area with at least 30 cm clearance on all sides.
- Electrical Requirements: Ensure a dedicated circuit rated for the unit’s current draw (≈10 A).
Mounting
- Attach the mounting brackets to the wall or support structure using corrosion‑resistant screws.
- Secure the condenser onto the brackets, aligning the refrigerant connections with the indoor unit.
- Use a torque wrench to tighten all fasteners to manufacturer specifications (typically 12 Nm).
Refrigerant Line Connection
- Connect the high‑pressure line from the condenser to the indoor evaporator using copper tubing and appropriate fittings.
- Attach the low‑pressure line in reverse, ensuring no cross‑connection.
- Check for leaks with a pressure gauge; a stable reading indicates proper sealing.
Electrical Wiring
- Connect the power supply to the condenser’s control board following the wiring diagram.
- Install a dedicated circuit breaker and ensure all connections are insulated.
- Verify correct polarity and grounding before energizing the system.
Key Features
- High Efficiency: The condenser’s copper fins and stainless steel housing maximize heat dissipation, lowering operating costs.
- Low Noise Operation: Designed with a quiet fan motor, it maintains indoor comfort without disturbing occupants.
- Durable Construction: Corrosion‑resistant materials resist harsh outdoor conditions for extended service life.
- Easy Maintenance: Accessible fins and removable panels allow quick cleaning and inspection.
- Eco‑Friendly Refrigerant: Uses R410A, which has zero ozone depletion potential (ODP) and a low global warming potential (GWP).
Maintenance & Troubleshooting
Regular upkeep ensures optimal performance. Follow these steps annually:
- Clean the fins: Remove dust with a soft brush or vacuum attachment.
- Inspect refrigerant lines: Look for kinks, corrosion, or leaks.
- Check fan operation: Ensure the motor runs smoothly and without vibration.
- Verify electrical connections: Tighten any loose terminals and inspect insulation integrity.
If the system fails to cool effectively, consider the following troubleshooting checklist:
- Low refrigerant charge – check for leaks.
- Blocked airflow – clean or replace filters.
- Faulty thermostat – verify settings and calibration.
- Electrical fault – inspect breakers and wiring.
Compatibility & Applications
The NRF 350084 is suitable for:
- Residential HVAC systems requiring 12 kW cooling capacity.
- Small commercial spaces such as offices, retail shops, or hospitality venues.
- Systems using R410A refrigerant, ensuring compliance with current environmental regulations.
Frequently Asked Questions
- Q: Can this condenser be used in extreme climates?
A: Yes, it operates effectively from –10 °C to +40 °C, making it suitable for most temperate regions.
- Q: How long does the installation take?
A: With proper preparation, a skilled technician can complete installation in 4–6 hours.
- Q: Is professional servicing required?
A: While routine maintenance can be performed by trained personnel, complex repairs should be handled by certified HVAC technicians.
Conclusion
The NRF 350084 Air‑Conditioning Installation combines robust engineering with user‑friendly design. Its high efficiency, low noise profile, and durable construction make it an ideal choice for both residential and commercial cooling solutions.
| This product in Comparor | |
|---|---|
|
Category
This product is cataloged in our store in these categories
|
- Condensers & secondary radiators for car air conditioning |
|
International
Find this product in one of our international stores
|
|
| Colors
Predominant colors of the product |
|
| Identifiers | |
| Brand | ![]() NRF is a brand that specializes in creating and selling clothing and accessories for women. The brand is known for its contemporary and stylish designs, as well as its high-quality materials. NRF is a popular choice for women who want to look stylish and fashionable, without spending a lot of money. |
| Model | NRF 350084 |
| MPN | NRF 350084 |
| ID | 7019248 |
| Dimensions / Weight | |
| Key Features | |